next up previous contents index
Next: Summary information Up: TestPump_abg.tex Previous: Subsystems   Contents   Index


Pump

Figure 3.3: System Pump: acausal bond graph
\fbox{
\includegraphics[width=0.9\linewidth,height=18cm,keepaspectratio]{/home/...
...ermal/Incompressible/Incompressible-Components/TestPump/MTT_work/Pump_abg.ps}
}

The acausal bond graph of system Pump is displayed in Figure 5.5 (on page [*]) and its label file is listed in Section 5.1.6 (on page [*]). The subsystems are listed in Section 5.1.6 (on page [*]).

Pump represents an ideal pump for incompressible fluid driving fluid though a Pipe component. The pipe component provides the correct thermal flow; if its resistance is set to zero, the pump is an ideal component.

The flow must be one way (in to out) for correct thermal properties.

The ports are
Hy_in
Pressure/volume-flow inflow
Hy_in
Pressure/volume-flow outflow
Th_in
Temperature/Entropy-flow in flow
Th_out
Temperature/Entropy-flow out flow
Shaft
Torque/angular velocity input.



Subsections
next up previous contents index
Next: Summary information Up: TestPump_abg.tex Previous: Subsystems   Contents   Index
http://mtt.sourceforge.net